Description

MedFlashII is an IPL (Intense Pulsed Light) system specifically designed for Beauty Clinics & Medi Spas. The unit allows the therapist to perform:

  • Hair Reduction

  • Skin Rejuvenation

  • Superficial Thread Vein Reduction

  • Active Acne Reduction

The unit features a large spot size (treatment area) of 50 X 25mm, allowing larger areas to be treated quickly. A series of clip on adapter windows are used to treat smaller areas such as the upper lip. As a double air cooled system no messy gel is required, the unit is also equipped with an optional skin cooling system. All the system options are software controlled via a colour touch screen, thus the system is easily upgraded. An optional client database feature to store, recall and track specific client treatments and settings is also available.

MedFlash  works by emitting a short safe flash of light from the hand piece. Dependent upon the hand piece in use, the light energy is used in different ways to achieve the treatments listed below.

Back to the top.

 

Treatments

Hair Reduction: Here the light energy emitted from the MedFlash 590nm to 1200nm hand piece is absorbed by the melanin in the hair shaft. Via a process called 'Selective Photo-thermolysis', the hair follicle is heated, this heat damages the follicle such that its ability to support hair re-growth is compromised. This heat damage is limited to the follicle itself and not the surrounding tissue.

 

Back to the top.

Skin Rejuvenation: Here the light energy emitted from the MedFlash 590nm to 1200nm hand piece is used to heat the dermal layer of the skin. This process has be shown to stimulate the production of collagen in the skin. Collagen is an amino acid in the skin which is primarily responsible for the skins elasticity.

The light energy is also absorbed by hemoglobin found in the blood of any  minor broken capillaries that are close to the skins surface. The hemoglobin  heats up and is destroyed thus reducing minor redness. (For more specific thread veins a separate hand piece is available).

Finally, minor sun spots in the skin contain melanin, when a particular type of light hits the melanin it too heats up briefly and is destroyed.

 

Back to the top.

Thread Veins

Here the light energy emitted from the MedFlash 520nm to 1200nm vascular hand piece targets the  hemoglobin found in the blood of superficial thread veins close to skins surface. The hemoglobin heats up, the heat then diffuses outwards either destroying the cells that make up the blood vessel wall or clotting the blood to stop the flow so that the individual vessels die. The dead cells are then removed by the body in the normal way.

 

Back to the top.

Active Acne

Here the light energy emitted from the MedFlash 390nm to 510nm acne hand piece targets the P.acne bacteria found in active acne pustules. The wavelength of the light energy emitted is absorbed by the pustule resulting in the production of oxygen within the pustule. The P.acne bacteria cannot survive in the presence of oxygen and thus the active pustules are reduced.

 

Back to the top.

 

Pictures

Click on a picture to enlarge it.

Back to the top.

MedFlash II unit with Integrated Skin Cooler

MedFlashes ergonomic hand piece

MedFlashes plug in lamp boxes

 

Specifications

Back to the top.

Standard wavelengths

590nm to 1200nm

Max total energy

600 Joules

Available power (fluence)

15 to 45 Joules per cm2 (at lamp level)

Emission mode

Single Pulse & Multiple Pulse

Max spot size

50mm X 25mm (35X15 & 20X10mm)

Skin Cooling -20C to 250C

Control panel

10.4" Colour Touch Screen

Lamp box life 15,000 shots

Available plug in lamp boxes

390nm to 510nm, 520nm to 1200nm

640nm to 1200nm, 510nm to 1200nm

Supply voltage 220V to 240V or 100 to 130V at 50/60Hz  
Power absorption 900VA
Protection Class 1, type BF (IEC 601-1)
Weight 42Kg with trolley

Max dimensions

600X400X1100mm

Approval CE 0476 FDA k051508

Back to the top.

 

Options

The system can be purchased with or without the integrated skin cooling system, although use of skin cooling system is highly recommended. (System without cooler badged as Flash 1 Plus)

By default the unit comes with the Hair Reduction / Skin Rejuvenation lamp box, additional Thread Vein, Dark Skin and Active Acne hand pieces are also available. An optional client database feature to store, recall and track specific client treatments and settings is also available.

All systems come with a 'Starter Pack'. This pack is designed to give you everything you need to get going with the machine i.e. training, brochures, consultation sheets, posters and suggested pricing.

Please Contact Us for unit pricing details.

Back to the top.

 

Distributed 
in Ireland by:  

Eden Beauty Group. 1 Main St., Wicklow Town, Co. Wicklow. IRELAND. 

Tel: + 353 (0)404 61295. Fax: + 353 (0)404 66684

E.& O. E. Copyright © 2005
Last modified: December 01, 2006